INSTALL INSTRUCTIONS C-3610-CV
PENTAX PRINTER MOUNT ‘96-08 FORD CROWN VICTORIA
TOOLS REQUIRED:
Power Drill
Drill Bit Set
Phillips Screwdriver
Wire Crimping Tool
HARDWARE:
QTY DESCRIPTION
PART #
3
3
5
1
#10 X ½” Sheet metal screw
GSM33194
GSM33195
CM86508
GSM33118
#10 X ¾” Sheet metal screw
#8 X 3/8” Black torx screw
#10 X ½” Machine screw
REMOVE:
1. Using Phillips screw driver, remove existing inner plastic glove box assembly.
(Do not remove glove box door)
INSTALLATION:
1. Subassembly:
• Position printer housing inside glove box
opening on left side. (Approximately 1”
inch from side)
• Using the housing hinge as a template,
mark the three mounting holes.
• The hinge rod should be above the glove
box fame. This is critical to allow the
glove box door to close.
• Drill (3) 9/64” holes
Housing Hinge Location
2. Glove box filler:
• The 2000 and newer model years
requires a glove box door filler (CM93605).
• Attach this filler with (5) #8 X 3/8” Black torx screws.
• On vehicle model years 1996-1999 – remove glove box retractor.
Note: 1999 and older models do not get this filler.
3. Mount Printer Housing:
Note: Printer should Not be in the housing yet.
• Mount housing assembly using (3) #10 x ¾” sheet metal screws.
(These screws go through the hinge and the holes you drilled in subassembly)
|